Technical Description
BSR-5136 is an addressable manual call point which activates the fire detection panel.BSR-5136 works with any panel supports Olympia A Protocol. It is essential to be placed in every fire detection system in co-operation with fire detection. At least one manual call pointhas to be placed in every fire detection system, close to the main control panel.
Pushing the clear plastic cover of the manual call point activates the alarm system.The clear plastic cover does not break but can be reset to its original position using the special plastic key which is included in the package.Periodic fire detection system testing can be carried out by activating a manual call point. It should be mounted in a clearly visible spot, near to the exit or ladder and at a height of 1.5 meters.
BSR-5136 is an addressable manual call point which activates the fire detection panel.BSR-5136 works with any panel supports Olympia A Protocol. It is essential to be placed in every fire detection system in co-operation with fire detection. At least one manual call pointhas to be placed in every fire detection system, close to the main control panel.
Pushing the clear plastic cover of the manual call point activates the alarm system.The clear plastic cover does not break but can be reset to its original position using the special plastic key which is included in the package.Periodic fire detection system testing can be carried out by activating a manual call point. It should be mounted in a clearly visible spot, near to the exit or ladder and at a height of 1.5 meters.
Additional specifications
– Resettable operating element with easy front access
– 160° viewable LED
– Semi flush or surface mounting
– Configurable as alarm or pre-alarm call point
– Resettable operating element with easy front access
– 160° viewable LED
– Semi flush or surface mounting
– Configurable as alarm or pre-alarm call point
Imporant Note
BSR-5136 features an intergrated short-circuit isolator which is automatically activated to isolate the faulty node from the rest of the loop. This feature allows to locate installation faults directly from the main panel.
Type | BSR-5136 |
Communication Protocol | Olympia A Protocol |
Main Voltage | 11-30V DC |
Standy Consumption | 90μA |
Alarm Consumption | 2.5mA (με το LED αναμμένο) |
Type | Type A |
Use | Σε εσωτερικούς χώρους |
Maximum loop current (Ic max, -L in/out) | 1A |
Maximum switch current (ls max, -L in/out) | 5A |
Maximum series resistance (Zc max, -L in-out | 50mΩ |
Maximum leakage current (lt max, -L in/out) | 25mA pulses (6ms/2 sec) |
Isolation voltage (Vso min-max) | 9.3 – 10.6 |
Reconnect voltage (Vsc min-max) | 10.7 – 12.7 |
Degrees of cover protection | IP20 |
Produced in accordance with | EN 54-11, EN-54-17 |
Operation temperature range | -40 to 70°C |
Relative Humidity | Up to 95% |
Construction materials | ABS/PC |
External dimensions | 94 x 98 x 56 mm |
Typical weight | 185gr. |
Guarantee | 2years |